Atmos DC30GSE wood gasification boiler 29.8 kW

by Atmos
Förderfähig
SKU 01.04.30
Original price 81,375.00 kr - Original price 81,375.00 kr
Original price
81,375.00 kr
81,375.00 kr - 81,375.00 kr
Current price 81,375.00 kr
inkl. MwSt., zzgl. Versand
Energieeffizienz A+
Availability:
in stock, ready to be shipped

The Atmos DC30GSE is a manually loaded wood gasification boiler with 29.8 kW output for central log heating systems with buffer tank. The GSE design combines a ceramic combustion chamber, induced draft fan, and electromechanical control for controlled log operation.

Wichtigste Vorteile

Wood gasification boiler from the ATMOS GSE series for central log wood heating systems

Robust design with ceramic combustion chamber and induced draft fan

Designed for operation with a sufficiently sized buffer tank

Fackhandel för värmeteknik

  • Teknisk rådgivning för värmeteknik & systemkomponenter
  • Säker betalning
  • Paket- eller speditionsfrakt beroende på produkttyp

GPSR-information

Name: Jaroslav Cankař a syn ATMOS

Address: elenského 487 294 21 Bělá pod Bezdězem, Cr

Email: info@atmos-zentrallager.de

Website: https://www.atmos.eu/de/

European Manufacturer: Yes

Legal guarantee rights

We provide the harmonised EU notice on the legal guarantee of conformity in advance. Mandatory use applies from 27/09/2026.

Any manufacturer's commercial guarantee is separate from this and is stated separately for the product where applicable.

Harmonised EU notice on the legal guarantee of conformity Official legal basis: Implementing Regulation (EU) 2025/1960

Product Overview & Application

The Atmos DC30GSE wood gasification boiler is a manually fed log wood boiler from the ATMOS GSE series for central hot water heating systems. With a boiler output of 29.8 kW, it is suitable for buildings with a corresponding heat demand where log wood is used as fuel and the heat is integrated into the heating system via a suitably sized buffer tank.

Technology & Equipment

The DC30GSE operates on the principle of wood gasification with reverse combustion. The boiler features a ceramic-lined combustion chamber, an induced draft fan, separately adjustable primary and secondary air, and electromechanical boiler control. A Belimo actuator is integrated into the boiler logic to limit the flue gas temperature. The standard design is intended for manual ignition.

Everyday Benefits

The GSE design combines a robust steel boiler construction with practical operation for log wood firing. The large loading door makes refueling easier, the induced draft fan supports the combustion process, and the automatic shutdown after the wood has burned out contributes to orderly operation of the fan and boiler circulation pump.

System Integration & Compatibility

The Atmos DC30GSE is designed for integration into a heating system with a sufficiently sized buffer tank. Proper hydraulic integration, return temperature boosting, and suitable chimney draft are important for operation. Planning should be tailored to the building, heat load, buffer volume, and existing heat distribution.

Technical Data Overview

The key technical data of the Atmos DC30GSE based on the available manufacturer documentation.

Nominal Output 29.8 kW
Fuel Log wood, dry
Combustion Technology Wood gasification
Efficiency 91.3 %
Energy Efficiency Class A+
Maximum Operating Pressure 2.5 bar
Maximum Log Length 530 mm
Boiler Class 5
Draft Requirement 20 Pa
Flue Gas Temperature 147.9 °C
Flue Pipe Connection 150/152 mm
Safety Heat Exchanger present
Buffer Tank Recommended yes
Ignition System manual
Height 1281 mm
Width 680 mm
Depth 1020 mm
Weight 466 kg
Voltage 230 V
Frequency 50 Hz
Power Consumption 50 W

Installation

Installation and integration of the boiler should be carried out by a qualified specialist company. For operation, a suitable chimney, return temperature boosting with a minimum return temperature of 65 °C, and a sufficiently sized buffer tank must be considered. The electrical connection is made to 230 V / 50 Hz.

Notes

Dry log wood with a moisture content of 12 to 20 % is intended for operation. The boiler operates in non-condensing mode and is designed for a boiler temperature in the range of 80 to 90 °C. Operation, cleaning, maintenance, and commissioning should be carried out according to the manufacturer's documentation.

Scope of Delivery

  • Atmos DC30GSE wood gasification boiler
  • Steel brush with accessories
  • Poker
  • Fill valve
  • Operating and maintenance manual
  • Honeywell FR 124 draft regulator
  • Ash pan
  • Device for pulling the braking devices out of the flue duct

Zu diesem Produkt wurden noch keine sauber darstellbaren produktspezifischen Fragen hinterlegt. Unser Fachteam unterstützt dich gerne bei technischen Fragen zur Auswahl, Montage oder Kompatibilität.

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare